Cerus Corporation Announces Positive Topline Results from Phase 3 RedeS Trial of the INTERCEPT Blood System for Red Blood Cells
The efficacy endpoint was met, while INTERCEPT-specific antibodies were detected without evidence of clinical impact.
Sentiment and the balance of points
Rhea-AI Sentiment reads the wording of the document, how positive or negative its language is on a 1 to 5 scale. The balance of points shown with the takes weighs what the document actually discloses, so the two can disagree, for example when a trial that missed its main goal is described in upbeat language.
- Met primary efficacy endpoint demonstrating non-inferiority of INTERCEPT Red Blood Cells (RBCs) to conventional RBCs by adjusted hemoglobin increment
- Primary safety endpoints:
- No statistically significant difference in related treatment-emergent adverse events (TEAEs) between treatment and control arms
- No evidence of hemolysis or clinical impact detected in treatment-emergent, low titer, transient antibodies, which were observed in RedeS, consistent with Cerus’ prior ReCePI study
“Over the past decade, pathogen reduction technology has become an integral component of the blood safety toolkit. The topline results from the RedeS study reinforce the potential to extend this established paradigm to red blood cell transfusions,” said Ross M. Fasano, MD, Professor of Pathology & Laboratory Medicine and Hematology at Emory University, and RedeS study site investigator at Grady Memorial Hospital.
RedeS Topline Results
The primary efficacy endpoint was met, demonstrating non-inferiority for INTERCEPT RBCs compared to conventional RBCs, as measured by adjusted hemoglobin increment, a commonly used measure of RBC transfusion effectiveness1. On a modified intent to treat (mITT) basis:
-
Adjusted hemoglobin increment was 1.996 g/dL (N=195) in the INTERCEPT arm compared with 2.050 g/dL (N=199) in the control arm, for an estimated difference of -0.054 g/dL (
95% CI, -0.210 to 0.103). -
The lower bound of the
95% confidence interval was above the prespecified non-inferiority margin of −0.32 g/dL, demonstrating non-inferiority (p=0.004).
The study was designed with two prespecified primary safety endpoints.
-
The proportion of subjects with any TEAEs (possibly, probably or definitely) related to a study RBC transfusion was
3.4% (n=9) in the INTERCEPT arm (N=267) compared with2.5% (n=7) in the control arm (N=276), with no statistically significant difference between treatment arms (p=0.634). -
As in Cerus’ prior ReCePI study, treatment-emergent, low titer, transient INTERCEPT-specific antibodies were detected in RedeS without evidence of hemolysis or clinical impact. The proportion of subjects with INTERCEPT RBC-specific antibodies was
2.2% (n=6) in the INTERCEPT arm (N=267), compared with zero in the control arm (N=276) (p<0.013). The six INTERCEPT RBC-specific antibodies observed in the treatment arm were included in the TEAE safety endpoint.
Full study results, including secondary endpoints, are expected to be submitted to a peer-reviewed scientific journal as well as presented at upcoming scientific meetings.
“Today, we took another important step toward extending pathogen reduction to red blood cells. The topline RedeS results provide additional evidence on the performance of INTERCEPT-treated red blood cells in patients requiring transfusion support and complement the earlier results from the STARS, SPARC, and ReCePI clinical studies,” said Dr. Richard Benjamin, Cerus’ chief medical officer. “Our sincere thanks go to the patients, investigators and blood centers whose participation made this study possible.”
Cerus has ongoing studies to further evaluate the nature of INTERCEPT RBC specific antibodies observed in clinical studies.
Development of the INTERCEPT Blood System for Red Blood Cells has been supported in whole or in part with federal funds from the Department of Health and Human Services; Administration for Strategic Preparedness and Response; Center for Biomedical Advanced Research and Development Authority (BARDA), under contract numbers HHSO100201600009C and 75A50124C00046.
The
The INTERCEPT Blood System for Red Blood Cells remains investigational in
Conference Call and Webcast
The Company will host a conference call at 4:30 P.M. ET this afternoon, during which management will discuss its third-quarter 2026 financial results, the RedeS topline results, and provide a general business overview and outlook. To listen to the live webcast, please visit the Investor Relations page of the Cerus website at http://www.cerus.com/ir.
A replay will be available on Cerus’ website approximately three hours after the call through November 23, 2026.
ABOUT CERUS
Cerus Corporation is dedicated solely to safeguarding the world’s blood supply and aims to become the preeminent global blood products company. Headquartered in
1. Roubinian NH, Plimier C, Woo JP, et al. Effect of donor, component, and recipient characteristics on hemoglobin increments following red blood cell transfusion. Blood. 2019;134(13):1003-1013. doi:10.1182/blood.2019000773 |
Cerus, INTERCEPT, and the Cerus logo are trademarks of Cerus Corporation.
Forward-Looking Statements
Except for the historical statements contained herein, this press release contains forward-looking statements concerning Cerus’ products, prospects and expected results, including statements relating to: the potential of the INTERCEPT Blood System for Red Blood Cells, including Cerus potentially making pathogen reduction available for RBCs; the significance and potential implications of the topline results from the RedeS clinical trial; Cerus’ expectations regarding completion of the full analysis of the RedeS data, including secondary endpoints, and publication and presentation of the full study results; Cerus’ ongoing evaluation of INTERCEPT RBC-specific antibodies observed in clinical studies; Cerus’ plans for further clinical and regulatory activities relating to INTERCEPT RBCs; the potential timing, scope and outcome of future interactions with the FDA and other regulatory authorities; Cerus’ ability to advance the INTERCEPT Blood System for Red Blood Cells toward regulatory submissions and potential approvals in
Actual results could differ materially from these forward-looking statements as a result of certain factors, including, without limitation: risks associated with the uncertain and time-consuming clinical development and regulatory review processes, including the risks that (a) Cerus may not complete a full analysis of the RedeS data or publish and present the full study results in a timely manner or at all, (b) the topline RedeS results reported herein and related findings and conclusions may change following completion of the full analysis of the study data, including secondary endpoints, (c) the full RedeS results may differ from or not support the conclusions suggested by the topline results, (d) additional analyses, clinical studies or other data may be required to support regulatory submissions or approvals for INTERCEPT RBCs, (e) Cerus and the FDA or other regulatory authorities may reach different conclusions regarding the RedeS results, INTERCEPT RBC-specific antibodies, the overall benefit-risk profile of INTERCEPT RBCs or the clinical or regulatory requirements necessary to support approval, (f) Cerus may be unable to complete planned clinical, regulatory or development activities in a timely manner or at all, (g) any regulatory submission for INTERCEPT RBCs may be delayed, may not be accepted for review, or may not be approved in a timely manner or at all, and (h) Cerus may be unable to obtain or maintain regulatory approvals for INTERCEPT RBCs in
View source version on businesswire.com: https://www.businesswire.com/news/home/20261102143597/en/
Tim Lee – Head of Investor Relations
Cerus Corporation
ir@cerus.com
925-288-6128
Source: Cerus Corporation