STOCK TITAN

Fluke Introduces New Refrigerated Calibration Baths for High-Accuracy Temperature Sensor Testing

Fluke (FTV) introduced three refrigerated temperature calibration baths designed for laboratories conducting high-accuracy testing of temperature sensors.

(Neutral)

Sentiment and the balance of points

Rhea-AI Sentiment reads the wording of the document, how positive or negative its language is on a 1 to 5 scale. The balance of points shown with the takes weighs what the document actually discloses, so the two can disagree, for example when a trial that missed its main goal is described in upbeat language.

Tags

Fluke (FTV) introduced three refrigerated temperature calibration baths designed for laboratories conducting high-accuracy testing of temperature sensors. The 7508, 7511 and 7512 models provide temperature control as low as –10 °C, with stated stability as precise as ±0.0007 °C and uniformity as precise as ±0.003 °C.

The company says the baths automate calibration tasks and data collection when paired with its 1586A Super-DAQ and MET/TEMP II software. Applications include calibrating platinum resistance thermometers, thermistors and thermocouples. An optional infrared cavity extends the 7508 model to infrared calibration.

Loading...
Loading translation...

Key Figures

Minimum operating temperature: –10 °C Temperature stability: ±0.0007 °C Temperature uniformity: ±0.003 °C
Minimum operating temperature
–10 °C
Refrigerated temperature calibration baths
Temperature stability
±0.0007 °C
Refrigerated temperature calibration baths
Temperature uniformity
±0.003 °C
Refrigerated temperature calibration baths

Key Terms

metrology, platinum resistance thermometer, thermistor, thermocouple
4 terms
metrology technical
"Engineered specifically for metrology rather than adapted from general laboratory equipment"
Metrology is the science and practice of making measurements accurate, consistent and traceable so numbers about size, weight, temperature or other properties mean the same thing everywhere. For investors it matters because reliable measurement underpins product quality, regulatory compliance and manufacturing efficiency—like using a well-calibrated ruler so every part fits—reducing recalls, legal risk and wasted costs that can affect a company’s earnings and reputation.
platinum resistance thermometer technical
"Applications include Platinum Resistance Thermometer (PRT), thermistor and thermocouple calibrations"
A platinum resistance thermometer is a precise temperature sensor that determines temperature by measuring how the electrical resistance of a platinum element changes with temperature. The platinum element is made and calibrated to a standardized resistance-versus-temperature curve (commonly ITS‑90), so the measured resistance is converted to a temperature value; common nominal types are Pt100 (100 ohms at 0 °C). It requires an electrical excitation and usually compensates for lead resistance; advantages include high stability and repeatability, while practical limitations include the need to avoid self‑heating from the excitation current and to account for lead and connection resistance in the measurement.
thermistor technical
"Applications include Platinum Resistance Thermometer (PRT), thermistor and thermocouple calibrations"
A thermistor is a small electrical sensor whose resistance changes predictably with temperature, acting like a thermometer made of electronic material. Investors care because thermistors are critical parts in many devices and production processes—affecting product performance, safety, manufacturing yield and regulatory compliance—so their availability, cost or improvements can influence a company’s costs, sales and competitive position much like a failing or better thermostat would change a building’s comfort and energy bill.
thermocouple technical
"Applications include Platinum Resistance Thermometer (PRT), thermistor and thermocouple calibrations"
A thermocouple is a temperature sensor made by joining two wires of different metals at one end so that a voltage is produced that depends on the temperature at the junction. The voltage is measured relative to a reference (cold) junction and converted to a temperature reading; different metal combinations give different temperature ranges and sensitivities, and accuracy can be affected by the quality of connections, reference-junction compensation, and electrical noise.

AI-generated analysis. How Rhea-AI works. Not financial advice.

See more from StockTitan in Google Search and AI answers. Adds StockTitan as a preferred source · opens Google
Add on Google

New calibration baths reduce temperature variability, minimize measurement uncertainty, and simplify demanding calibration workflows

Eindhoven, Netherlands, Oct. 28, 2026 (GLOBE NEWSWIRE) -- As calibration laboratories face growing demands for accuracy, repeatability and efficiency, even small temperature variations can introduce uncertainty and compromise confidence in calibration results. Maintaining a precise, uniform temperature environment, particularly at low temperatures can be challenging, adding complexity to already demanding calibration workflows. Addressing these challenges, Fluke today announced the 7508, 7511 and 7512 Refrigerated Temperature Calibration Baths, designed to deliver exceptional temperature stability and uniformity while automating critical calibration tasks.

Engineered specifically for metrology rather than adapted from general laboratory equipment, the refrigerated baths provide temperature control as low as –10 °C, with stability as precise as ±0.0007 °C and uniformity as precise as ±0.003 °C. The baths are designed to eliminate temperature gradients through balanced stirring while precisely managing heating and cooling to maintain a consistent environment for calibration.

"Fluke Calibration baths have a long legacy in metrology labs because their specifications mean something," said Ron Ainsworth, Senior Product Manager at Fluke Calibration. "The 7508, 7511 and 7512 keep the stability and uniformity metrologists trust and carry that legacy forward on a modernized platform that's easier to use, connect, automate and maintain."

The 7508/7511/7512 baths automate temperature sensor calibration when paired with the Fluke Calibration 1586A Super-DAQ and MET/TEMP II software. Computer-controlled solenoid valves precisely balance the heating and cooling system, while the software automates calibration tasks and data collection. The system supports USB and RS-232 connectivity and is designed for future support of CalStudio.

Available in multiple configurations, the baths support the calibration and testing of temperature sensors used across manufacturing, R&D and test-and-measurement applications, ranging from verifying industrial temperature controllers to maintaining highly accurate laboratory reference standards. Applications include Platinum Resistance Thermometer (PRT), thermistor and thermocouple calibrations, as well as maintaining triple-point-of-water cells. An optional 2033 IR cavity can be integrated into the 7508 bath to support precision infrared calibration applications.

The baths also are designed to simplify day-to-day operation and maintenance. The new baths incorporate automation, data collection capabilities and an updated user interface that help reduce setup complexity and operator intervention.

Direct-drive stirrer motors, pump-free balanced stirring and full fluid drainage help simplify maintenance and support reliable performance over time. The baths use CFC-free refrigerants.

 With increasingly precise measurements driving the evolution of modern calibration laboratories, Fluke’s refrigerated baths are designed to help labs establish a more controlled, automated and repeatable approach to temperature calibration.

For more information about the 7508/7511/7512 Refrigerated Temperature Calibration Baths, visit Fluke Calibration.

About Fluke
Founded in 1948, Fluke Corporation is the world leader in compact, professional electronic test tools and software for measuring and condition monitoring. Fluke customers are technicians, engineers, electricians, maintenance managers, and metrologists who install, troubleshoot, and maintain industrial, electrical, and electronic equipment and calibration processes. Fluke is a registered trademark of Fluke Corporation. For more information, visit the Fluke website.

# # #
FLUKE is a registered trademark of Fluke Corporation. For more information, visit the Fluke website.

For more information:
Dave Smith 
Fluke Corporation
dave.smith@fluke.com

Olivia Kline
Fluke Corporation
olivia.kline@fluke.com

1) What is the 75xx Series?
The 7508, 7511 and 7512 are refrigerated temperature calibration baths that create a highly stable, uniform temperature environment for calibrating sensors such as PRTs, thermistors and thermocouples. They operate down to –10 °C and combine precision temperature control with automation and maintenance-focused design.

2) Why are the baths important for metrologists?
A calibration bath provides the controlled temperature environment metrologists need to determine whether a sensor is measuring accurately, rather than introducing uncertainty from temperature fluctuations or gradients. The more stable and uniform the bath, the greater the confidence in the calibration results.

3) What are the benefits for Calibration labs?
The new baths can help labs achieve more consistent, repeatable calibration results while reducing manual intervention through automation. They also simplify operation and maintenance, helping technicians improve productivity without compromising measurement confidence.

 

Attachments